Industrial and rubber cable
Industrial cable is flexible power cable that moves, withstands oil or survives a construction site: H07RN-F, H07BQ-F with PUR sheath and the halogen-free armoured RZ1MZ1-K(AS) for hazardous areas where EN 60079-14 calls for an armoured cable. Q Cables supplies these types to order and states the lead time with the price.
Types in this category
H07BQ-F
Flexible EPR/PUR rubber cable, class 5 Cu, 90 °C
Lead time: On request; the lead time is stated in the quote.
H05BQ-F
PUR-sheathed rubber flexible cable, 300/500 V
Lead time: On request; the lead time is stated in the quote.
RZ1MZ1-K(AS)
Halogen-free armoured power cable 0.6/1 kV, XLPE/LSZH/SWA/LSZH
Lead time: On request; the lead time is stated in the quote.
H05VV-F
PVC flexible cord, 300/500 V
Lead time: On request; the lead time is stated in the quote.
H05VVH2-F
PVC flat flexible cord, 300/500 V
Lead time: On request; the lead time is stated in the quote.
H03VV-F
PVC light flexible cord, 300/300 V
Lead time: On request; the lead time is stated in the quote.
H03VVH2-F
PVC light flat flexible cord, 300/300 V
Lead time: On request; the lead time is stated in the quote.
H05Z1Z1-F
LSZH flexible cable, halogen-free, 300/500 V
Lead time: On request; the lead time is stated in the quote.
H03Z1Z1-F
LSZH light flexible cord, halogen-free, 300/300 V
Lead time: On request; the lead time is stated in the quote.
H07RN-F
Rubber flexible cable, 450/750 V
Lead time: On request; the lead time is stated in the quote.
H05RN-F
Light rubber flexible cable, polychloroprene sheath, 300/500 V
Lead time: On request; the lead time is stated in the quote.
H05RR-F
Rubber flexible cable, 300/500 V
Lead time: On request; the lead time is stated in the quote.
H07BN4-F
Heavy-duty rubber flexible cable, 450/750 V
Lead time: On request; the lead time is stated in the quote.
H07ZZ-F
LSZH cross-linked flexible cable, halogen-free, 450/750 V
Lead time: On request; the lead time is stated in the quote.
NSHTOEU
Heavy rubber reeling and trailing cable, 0.6/1 kV
Lead time: On request; the lead time is stated in the quote.
NSSHOEU
Heavy rubber trailing cable, 0.6/1 kV
Lead time: On request; the lead time is stated in the quote.
NSGAFOEU
Single-core rubber cable, 1.8/3 kV
Lead time: On request; the lead time is stated in the quote.
PUR drag-chain cable JZ
PUR continuous-flex control cable for drag chains, 300/500 V
Lead time: On request; the lead time is stated in the quote.
Motor cable 2YSLCY-J
Screened motor connection cable for frequency converters (VFD), 0.6/1 kV
Lead time: On request; the lead time is stated in the quote.
H01N2-D
Rubber arc-welding cable, 100/100 V
Lead time: On request; the lead time is stated in the quote.
H01N2-E
Rubber arc-welding cable, high flexibility, 100/100 V
Lead time: On request; the lead time is stated in the quote.
H05SS-F
Silicone rubber flexible cable, 300/500 V
Lead time: On request; the lead time is stated in the quote.
SiHF
Silicone rubber flexible cable, 300/500 V
Lead time: On request; the lead time is stated in the quote.
SiF
Silicone rubber single-core wire, 300/500 V
Lead time: On request; the lead time is stated in the quote.
NHXH FE180
Halogen-free fire-resistant power cable, 0.6/1 kV, FE180 E30–E90
Lead time: On request; the lead time is stated in the quote.
BS 7846
Fire-resistant XLPE/SWA/LSZH armoured power cable, 600/1000 V
Lead time: On request; the lead time is stated in the quote.
BS 7846 F120
Fire-resistant armoured power cable, F120, 600/1000 V
Lead time: On request; the lead time is stated in the quote.
Flexible where fixed cable does not fit
H07RN-F (also known as NWPK) is the heavy-duty rubber cable for 450/750 V: EPR insulation and a polychloroprene sheath that resists oil, weather, ozone and UV. For tools, machines, pumps and temporary supply, indoors, outdoors and, in the permitted sizes, in water. It is not intended for continuous reeling or forced guidance.
H07BQ-F is the construction-site cable: rubber insulation (EPR) with a polyurethane sheath that resists oil, abrasion and impact, down to −30 °C flexing and −40 °C fixed. For tools, temporary supply and anything dragged across the ground.
Halogen-free and armoured for hazardous areas
RZ1MZ1-K(AS) is the armoured, halogen-free power cable for petrochemical plants, service stations and flammable product stores. The steel wire armour protects against mechanical damage. The polyolefin sheaths emit little smoke and no halogen in a fire, and the cable has reaction-to-fire class Cca. Recommended in hazardous areas where EN 60079-14 calls for an armoured cable, and wherever the cable is exposed to damage.
(AS) stands for Alta Seguridad (high safety): halogen-free and non-fire-propagating, with little smoke and low acidity; that is not the same as fire-resistant (AS+). AS+ maintains circuit integrity during a fire. For emergency systems the specification usually requires AS+ with a PH class.
Supplied to order
These types are not held in stock in Dordrecht. We supply them to order, with the lead time in the quote. Non-standard sheath colours, core counts or lengths are produced to your specification.
| Type | Voltage | CPR | Standard | Conductor | Availability and lead time |
|---|---|---|---|---|---|
| H07BQ-F | 450/750 V | - | EN 50525-2-21 (HD 22.10) | Fine-wire strand of plain annealed copper, class 5 acc. to IEC 60228 | On request The lead time is stated in the quote. |
| H05BQ-F | 300/500 V | - | EN 50525-2-21 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| RZ1MZ1-K(AS) | 0.6/1 kV | Cca-s1b,d1,a1 | IEC 60502-1 | Flexible electrolytic copper conductor, class 5, according to UNE-EN 60228 | On request The lead time is stated in the quote. |
| H05VV-F | 300/500 V | - | EN 50525-2-11 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H05VVH2-F | 300/500 V | - | EN 50525-2-11 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H03VV-F | 300/300 V | - | EN 50525-2-11 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H03VVH2-F | 300/300 V | - | EN 50525-2-11 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H05Z1Z1-F | 300/500 V | - | EN 50525-3-11 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H03Z1Z1-F | 300/300 V | - | EN 50525-3-11 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H07RN-F | 450/750 V | - | EN 50525-2-21 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H05RN-F | 300/500 V | - | EN 50525-2-21 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H05RR-F | 300/500 V | - | EN 50525-2-21 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H07BN4-F | 450/750 V | - | EN 50525-2-21 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H07ZZ-F | 450/750 V | - | EN 50525-3-21 | Fine-wire stranded plain (bare) annealed copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| NSHTOEU | 0.6/1 kV | - | VDE 0250-814 | Fine-wire stranded tinned annealed copper, class 5 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| NSSHOEU | 0.6/1 kV | - | VDE 0250-812 | Fine-wire stranded tinned annealed copper, class 5 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| NSGAFOEU | 1.8/3 kV | - | VDE 0250-602 | Fine-wire stranded tinned annealed copper, class 5 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| PUR drag-chain cable JZ | 300/500 V | - | VDE 0285-525 | Extra-finely stranded bare annealed copper, class 5/6 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| Motor cable 2YSLCY-J | 0.6/1 kV | Eca | EN 50525 / EMC EN 55011 | Finely stranded bare annealed copper, class 5 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| H01N2-D | 100/100 V | - | EN 50525-2-81 (HD 22.6) | Very fine-wire stranded bare (plain) annealed copper, class 6 (to 95 mm²) or class 5 (from 120 mm²) to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H01N2-E | 100/100 V | - | EN 50525-2-81 (HD 22.6) | Very fine-wire stranded bare (plain) annealed copper, class 6 (to 95 mm²) or class 5 (from 120 mm²) to IEC/EN 60228 | On request The lead time is stated in the quote. |
| H05SS-F | 300/500 V | - | EN 50525-2-83 | Fine-wire stranded tinned (metal-coated) copper, class 5 to IEC/EN 60228 | On request The lead time is stated in the quote. |
| SiHF | 300/500 V | - | VDE 0250 / EN 50525-2-83 | Fine-wire stranded tinned (metal-coated) copper, class 5 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| SiF | 300/500 V | - | VDE 0250 | Fine-wire stranded tinned (metal-coated) copper, class 5 to IEC/EN 60228 (VDE 0295) | On request The lead time is stated in the quote. |
| NHXH FE180 | 0.6/1 kV | Eca | VDE 0266 / IEC 60331 | Plain (bare) annealed copper, solid class 1 or stranded class 2 acc. to IEC 60228 / VDE 0295 | On request The lead time is stated in the quote. |
| BS 7846 | 0.6/1 kV | - | BS 7846 | Stranded plain annealed copper, class 2 acc. to BS EN 60228 / IEC 60228 | On request The lead time is stated in the quote. |
| BS 7846 F120 | 0.6/1 kV | - | BS 7846 / BS 8491 | Stranded plain annealed copper, class 2 acc. to BS EN 60228 / IEC 60228 | On request The lead time is stated in the quote. |
What does (AS) mean in RZ1MZ1-K(AS)?
The Spanish designation for halogen-free and non-flame-propagating: little smoke, no halogen and low acidity in a fire. AS+ adds fire resistance (circuit integrity).
How fast can you supply industrial cable?
That depends on type, cross-section and length. We state the lead time in the quote and keep to it. On larger projects we agree the length breakdown and deliver in phases on call-off.
Why not every cable has a CPR class
Which cables fall outside EN 50575, why that differs from Fca, and what to report back when the specification demands a class for a type that has none.
Read the article →Drums, lengths and cutting loss
How length choice drives the project price.
Read the article →Fire resistant or flame retardant: what is the difference?
Four properties that get mixed up in specifications: flame retardant, fire resistant, halogen-free and the CPR class.
Read the article →Quote
Request industrial and rubber cable
Send the type or application, cross-section and length, and we will respond quickly.
Not seeing what you need? Just ask. Our range goes well beyond this list.