Skip to content
Industrial & rubber

H07BQ-F

Flexible EPR/PUR rubber cable, class 5 Cu, 90 °C

450/750 V EN 50525-2-21 (HD 22.10)
CU/EPR/PUR On request Lead time: On request; the lead time is stated in the quote. Send your enquiry
Application

H07BQ-F is the site cable with a polyurethane (PUR) sheath: fine-stranded class 5 copper, EPR rubber insulation for 90 °C and a sheath that withstands dragging, oil and cold. Can be flexed down to −30 °C and installed fixed down to −40 °C. For tools, site distribution boards and temporary outdoor connections under heavy mechanical stress.

H07BQ-F is a heavy-duty flexible cable to EN 50525-2-21 (HD 22.10) for 450/750 V connection of power tools, site equipment, hoists, pumps and machinery under tough mechanical and chemical conditions. The fine-stranded class 5 copper conductors are insulated with cross-linked ethylene-propylene rubber (EPR/EI6), laid up, and protected by an abrasion-, oil- and weather-resistant polyurethane (PUR) outer sheath. The PUR sheath and rubber insulation make the cable tough, cold-flexible and resistant to oils, greases and mechanical wear, so H07BQ-F is used where ordinary PVC or rubber flexibles would not survive. The cross-linked EPR insulation (EI6) gives a +90 °C conductor rating.

Construction siteOil & abrasion resistantCold

Also known as: PUR cable

Applications

  • Construction sites: connecting tools and site distribution boards that drag over the ground.
  • Cold stores and outdoors in winter: flexing down to −30 °C, fixed down to −40 °C.
  • Workshops with oil and coolant: the PUR sheath is abrasion and oil resistant.

What to look out for

  • Outside the scope of the CPR: for fixed installation in buildings where the Bbl requires a fire class, choose an installation cable such as YMvK Cca.
  • Class 5: ferrules in plugs and enclosures.
  • On long site cables (over 50 m) check the voltage drop; 2.5 mm² is often too small then.
Construction
Conductor
Fine-wire strand of plain annealed copper, class 5 acc. to IEC 60228.
Insulation
Cross-linked ethylene-propylene rubber (EPR), type EI6.
Core identification
Colour-coded per HD 308 S2 (with green/yellow), or numbered per order.
Sheath
Polyurethane (PUR / TMPU), abrasion-, oil- and weather-resistant; typically orange.
Electrical & thermal properties
Rated voltage Uo/U
450/750 V.
Test voltage
2.5 kV AC.
Standard
EN 50525-2-21 (HD 22.10); conductor acc. to IEC 60228, class 5.
Reaction to fire (CPR)
Outside the scope of EN 50575 (flexible connection cable).
Flame-retardant
IEC/EN 60332-1-2.
Max. conductor temperature
+90 °C (short circuit +250 °C, max. 5 s).
Permitted outer cable temperature, flexing
−30 °C to +80 °C.
Permitted outer cable temperature, fixed
−40 °C to +90 °C.
Min. bending radius
4 × overall diameter (fixed), 6 × overall diameter (flexing).
Dimensions and technical data

Sizes and weights

Cores × mm²R DC 20 °C (Ω/km)Outer Ø approx. (mm)Weight approx. (kg/km)
2×1.513.37.679
3×1.513.38100
4×1.513.39126
5×1.513.39.8148
2×2.57.989117
3×2.57.989.6150
4×2.57.9810.7188
5×2.57.9811.9228
2×44.9510.6188
3×44.9511.3240
4×44.9512.7300
5×44.9514.1362
2×63.311.8234
3×63.312.8311
4×63.314.2391
5×63.315.7474
2×101.9115.6387
3×101.9116.8512
4×101.9118.6642
5×101.9120.4775
2×161.2117.9552
3×161.2119.5748
4×161.2121.3935
5×161.2123.71141

H07BQ-F starts at 1.5 mm². The 0.75 and 1 mm² sizes are H05BQ-F, for 300/500 V.

Which one do I choose?

H07BQ-F or H07RN-F?

H07BQ-F

  • PUR sheath
  • 90 °C conductor temperature

H07RN-F

  • polychloroprene sheath
  • 60 °C conductor temperature

Both are flexible 450/750 V cables with EPR insulation. H07BQ-F has a PUR sheath that is more abrasion-resistant than the polychloroprene sheath of H07RN-F, and is designed for a 90 °C conductor temperature instead of 60 °C. H07RN-F does come in much larger cross-sections, single-core up to 630 mm². Choose H07BQ-F for tools and cables that are dragged across the site a lot, and H07RN-F for heavy supplies and large cross-sections.

View H07RN-F →

H07BQ-F or H05BQ-F?

H07BQ-F

  • 450/750 V
  • up to 16 mm²
  • site distribution boards

H05BQ-F

  • 300/500 V
  • 0.75 and 1 mm²
  • hand tools

The same construction, EPR insulation under a PUR sheath, but a different voltage class. H05BQ-F is 300/500 V and comes in 0.75 and 1 mm², for hand tools and portable equipment. H07BQ-F is 450/750 V and goes up to 16 mm², for site distribution boards and heavier connections. If you need more than 1 mm², or the connection calls for 450/750 V, choose H07BQ-F.

View H05BQ-F →