Skip to content

Underground cable

In short

Underground cable is power cable for buried installation, with a braid (VO-YMvKas) or armour (VG-YMvKas) against mechanical damage. Q Cables holds VO-YMvKas up to 4×6 mm² and VG-YMvKas up to 4×240 mm² in stock in Dordrecht: ordered before 12:00, usually on site within 1–2 working days. Aluminium and NAYCWY on request.

Types in this category

3D view of the construction of VO-YMvKas Dca
CU/XLPE/PVC/GSWB/PVC In stock

VO-YMvKas Dca

Braid-armoured installation cable 0.6/1 kV, Cu/XLPE/PVC/GSWB/PVC, 90 °C

Lead time: 1–2 working days from stock

In stock: 2×2.5 · 2×4 · 2×6 · 3×2.5 · 3×6 +3

0.6/1 kV CPR Dca HD 604-S1-4D →
3D view of the construction of VG-YMvKas Dca
CU/XLPE/PVC/GSWA+ECC/PVC In stock

VG-YMvKas Dca

Power cable 0.6/1 kV, XLPE, steel wire armoured

Lead time: 1–2 working days from stock

In stock: 2×10 · 2×16 · 3×10 · 3×16 · 4×10 +9

0.6/1 kV CPR Dca HD 604-S1-4D →
3D view of the construction of VG-YMvKas Dca ALU
AL/XLPE/PVC/GSWA+ECC/PVC On request

VG-YMvKas Dca ALU

Power cable 0.6/1 kV, aluminium conductor, armoured

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Dca HD 604 S1 / IEC 60502-1 →
3D view of the construction of VG-YMvKas AL/AL Cca
AL/XLPE/PVC/AWA/PVC On request

VG-YMvKas AL/AL Cca

Dutch armoured aluminium power cable, aluminium wire armour, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Cca HD 604 S1 →
3D view of the construction of N2XRH-J
CU/XLPE/HFFR/GSWA/HFFR On request

N2XRH-J

Halogen-free armoured power cable, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca IEC 60502-1 →
3D view of the construction of NAYCWY Eca
AL/PVC/CU(conc.)/PVC On request

NAYCWY Eca

Power cable 0.6/1 kV, aluminium conductor, concentric copper conductor

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca DIN VDE 0276-603 →
3D view of the construction of NYY
CU/PVC/PVC On request

NYY

PVC power / underground cable, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca DIN VDE 0276-603 (HD 603) →
3D view of the construction of NAYY
AL/PVC/PVC On request

NAYY

Aluminium PVC power / underground cable, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca DIN VDE 0276-603 (HD 603) →
3D view of the construction of NYCWY
CU/PVC/CWS/PVC On request

NYCWY

PVC power cable with concentric conductor, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca DIN VDE 0276-603 (HD 603) →
3D view of the construction of XFVB
CU/XLPE/PVC/STA/PVC On request

XFVB

Belgian NBN steel-tape armoured installation cable, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Cca NBN HD 604-4-G →
3D view of the construction of EXVB
CU/XLPE/PVC/PVC On request

EXVB

Belgian NBN copper outdoor cable (reinforced-sheath XVB), 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca NBN HD 603-5A →
3D view of the construction of EXAVB
CU/XLPE/CU-PC/STA/PVC On request

EXAVB

Belgian NBN armoured underground cable, XLPE, black PVC sheath, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Cca NBN HD 603-6E →
3D view of the construction of EXGB
CU/XLPE/LSZH/LSZH On request

EXGB

Belgian NBN copper halogen-free outdoor cable, Cca, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Cca NBN HD 603-5A →
3D view of the construction of EAXeVB
AL/XLPE/PVC/PVC On request

EAXeVB

Belgian NBN aluminium installation/distribution cable (aluminium EXVB, longitudinally watertight), 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca NBN HD 603-5A →
3D view of the construction of EAXeGB
AL/XLPE/LSZH/LSZH On request

EAXeGB

Belgian NBN aluminium halogen-free cable (aluminium EXGB), Cca, 0.6/1 kV

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Cca NBN HD 603-5A →
3D view of the construction of BS 5467
CU/XLPE/PVC/GSWA/PVC On request

BS 5467

XLPE/SWA/PVC armoured power cable, 600/1000 V

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Eca BS 5467 →
3D view of the construction of BS 6724
CU/XLPE/LSZH/GSWA/LSZH On request

BS 6724

XLPE/SWA/LSZH armoured power cable, halogen-free, 600/1000 V

Lead time: On request; the lead time is stated in the quote.

0.6/1 kV CPR Dca BS 6724 →

Braided or armoured

Underground cable has to take a knock: a spade, ground settlement or a stone in the trench. VO-YMvKas has a braid of galvanised steel wire (GSWB) with an underlying tinned-copper earth strand that serves as the earth. VG-YMvKas has an armour of galvanised steel wire with a steel tape counter helix (GSWA+ECC). The armour is heavier and protects better against pulling forces and mechanical damage.

Both have XLPE insulation, a flame-retardant PVC sheath, 0.6/1 kV, reaction-to-fire class Dca and approval to DEKRA K42D-1-1:2017 and DEKRA K42D-1-4-D:2017 (formerly KEMA-KEUR). The maximum conductor temperature is 90 °C, or 250 °C in a short circuit, per HD 604-S1-4D.

Copper or aluminium

On large cross-sections and long routes the copper price is a major cost factor. The VG-YMvKas Dca ALU is the aluminium version of the armoured cable, with reaction-to-fire class Dca; Cca we supply on request. NAYCWY combines an aluminium conductor with a concentric copper conductor and is rated for installation in water and concrete. Aluminium needs over one and a half times the cross-section of copper for the same resistance, but the conductor then still weighs about half.

The choice mostly comes down to the connections: aluminium needs connectors approved for aluminium, contact grease and bimetallic transitions. We calculate both variants if you send the length, load and voltage level.

Lengths, drums and cutting loss

Underground cable comes on drums of 250, 500 or 1,000 metres; heavy cross-sections in shorter lengths because the drum weight would otherwise be unmanageable. A 1,000-metre drum of 4×240 mm² has to be handled by crane. For project deliveries we agree the length breakdown before production and deliver in phases on call-off, so you do not pay for remnants.

Side by side
Type Voltage CPR Standard Conductor Availability and lead time
VO-YMvKas Dca 0.6/1 kV Dca-s2,d2,a3 HD 604-S1-4D Plain annealed copper, solid class 1 acc. to IEC 60228 In stock 1–2 working days from stock
VG-YMvKas Dca 0.6/1 kV Dca-s2,d2,a3 HD 604-S1-4D Stranded copper, class 2 In stock 1–2 working days from stock
VG-YMvKas Dca ALU 0.6/1 kV Dca-s2,d2,a3 HD 604 S1 / IEC 60502-1 Stranded aluminium, class 2 acc. to IEC 60228, sector-shaped On request The lead time is stated in the quote.
VG-YMvKas AL/AL Cca 0.6/1 kV Cca-s2,d2,a3 HD 604 S1 Aluminium, sector-shaped stranded (svs), class 2 acc. to IEC 60228 On request The lead time is stated in the quote.
N2XRH-J 0.6/1 kV Eca IEC 60502-1 Stranded plain copper, class 2 acc. to IEC 60228 On request The lead time is stated in the quote.
NAYCWY Eca 0.6/1 kV Eca DIN VDE 0276-603 Aluminium, solid (class 1) or stranded (class 2) acc. to IEC 60228, round or sector-shaped On request The lead time is stated in the quote.
NYY 0.6/1 kV Eca DIN VDE 0276-603 (HD 603) Plain (bare) copper, solid class 1 or stranded class 2 acc. to IEC 60228 / DIN VDE 0295; circular (RE/RM) or sector-shaped (SM) in the larger multicore sizes On request The lead time is stated in the quote.
NAYY 0.6/1 kV Eca DIN VDE 0276-603 (HD 603) Aluminium, solid class 1 or stranded class 2 acc. to IEC 60228 / DIN VDE 0295; circular (RE/RM) or sector-shaped (SE/SM) in the larger multicore sizes On request The lead time is stated in the quote.
NYCWY 0.6/1 kV Eca DIN VDE 0276-603 (HD 603) Plain (bare) copper phase conductor, solid class 1 or stranded class 2 acc. to IEC 60228 / DIN VDE 0295 On request The lead time is stated in the quote.
XFVB 0.6/1 kV Cca-s3,d2,a3 NBN HD 604-4-G Plain annealed copper, solid class 1 (RE) or stranded class 2 (RM) acc. to IEC 60228 On request The lead time is stated in the quote.
EXVB 0.6/1 kV Eca NBN HD 603-5A Plain annealed copper, solid class 1 (RE) or stranded class 2 (RM/SM) acc. to IEC 60228 On request The lead time is stated in the quote.
EXAVB 0.6/1 kV Cca-s3,d2,a3 NBN HD 603-6E Bare copper, solid class 1 or stranded class 2 acc. to IEC 60228; sector-shaped stranded conductors from 70 mm² On request The lead time is stated in the quote.
EXGB 0.6/1 kV Cca-s1,d2,a1 NBN HD 603-5A Plain annealed copper, solid class 1 (RE) or stranded class 2 (RM/SM) acc. to IEC 60228 On request The lead time is stated in the quote.
EAXeVB 0.6/1 kV Eca NBN HD 603-5A Aluminium, solid class 1 (RE) or stranded class 2 (RM) acc. to IEC 60228 On request The lead time is stated in the quote.
EAXeGB 0.6/1 kV Cca-s1,d2,a1 NBN HD 603-5A Aluminium, solid class 1 (RE) or stranded class 2 (RM) acc. to IEC 60228 On request The lead time is stated in the quote.
BS 5467 0.6/1 kV Eca BS 5467 Plain annealed copper, class 2 stranded to BS EN 60228; circular, or shaped in the larger multicore sizes On request The lead time is stated in the quote.
BS 6724 0.6/1 kV Dca-s1,d2,a1 BS 6724 Plain annealed copper, class 2 (stranded) acc. to BS EN 60228 On request The lead time is stated in the quote.
Frequently asked questions
What exactly is in stock?

VO-YMvKas Dca up to 4×6 mm², VG-YMvKas Dca from 2×10 up to 4×240 mm², plus YMvK Cca. Send the cross-section and length, and we quickly confirm what can ship from stock.

VO or VG: which do I choose?

VG (armoured) where the cable risks mechanical damage or pulling force: under roads, in industry and on long pulls. VO (braided) for standard underground supply where the braid suffices for protection and earthing.

Can you supply to route length?

Yes. From stock we cut to length; for production orders the cable is made to route length. That way you do not pay for cutting loss you never use.

Read more

Quote

Request underground cable

Send cross-section, length and the drum lengths you need. What is in Dordrecht we confirm quickly, often the same working day; the rest comes with a lead time attached.

Not seeing what you need? Just ask. Our range goes well beyond this list.

Send your enquiry

Include cross-section, length and required delivery date, and we can get straight to work.

1Which cable?
Type unknown? Fill in the specification (optional)
2How much and when?
3Your details
A fast response on working days, often the same working day. No account and no webshop: one email is enough.

Have a cable list (Excel, CSV or PDF)? Email it to info@qcables.nl and we will include it in the quote.

By sending your enquiry you agree to our privacy policy. We use your details only to handle your enquiry.