Skip to content

Control and signal cable

In short

Control and signal cable links switchboards, machines and control systems. The control cables are rated 300/500 V, the Li data cables such as LiYCY 250 V. Unscreened types such as YSLY-JZ and YSLY-OZ suit areas without interference. Where drives or sensitive signals run alongside, choose a screened YSLYCY-JZ or LiYCY, and where the cable needs mechanical protection the steel-braided YSLYSY-JZ. Fine-stranded copper for flexibility. LiYCY, LiYCY-TP and LiHCH-TP are in stock; we supply the other types to order, with the lead time stated in the quote.

Types in this category

3D view of the construction of LiHCH-TP
CU/LSZH/TCWB/LSZH In stock

LiHCH-TP

LSZH flexible data cable, twisted pairs, screened

Lead time: 1–2 working days from stock

In stock: 6×2×0.5

250 V DIN VDE 0812 →
3D view of the construction of LiYCY
CU/PVC/TCWB/PVC In stock

LiYCY

PVC flexible data cable, screened

Lead time: 1–2 working days from stock

In stock: 4×0.5 · 5×0.25 · 6×0.5 · 10×0.25

250 V CPR Eca DIN VDE 0812 →
3D view of the construction of LiYCY-TP
CU/PVC/TCWB/PVC In stock

LiYCY-TP

PVC flexible data cable, twisted pairs, screened

Lead time: 1–2 working days from stock

In stock: 4×2×0.75

250 V CPR Eca DIN VDE 0812 →
3D view of the construction of YSLY-JZ
CU/PVC/PVC On request

YSLY-JZ

PVC flexible control cable, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V CPR Eca EN 50525-2-51 →
3D view of the construction of YSLY-OZ
CU/PVC/PVC On request

YSLY-OZ

PVC flexible control cable without earth core, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V CPR Eca EN 50525-2 →
3D view of the construction of YY-LSZH
CU/LSZH/LSZH On request

YY-LSZH

LSZH flexible control cable, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V CPR Dca EN 50525-3-11 →
3D view of the construction of YSLYCY-JZ
CU/PVC/TCWB/PVC On request

YSLYCY-JZ

PVC screened flexible control cable, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V CPR Eca EN 50525-2-51 →
3D view of the construction of YSLYCY-OZ
CU/PVC/TCWB/PVC On request

YSLYCY-OZ

PVC screened flexible control cable without earth core, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V CPR Eca EN 50525-2-51 →
3D view of the construction of YSLYSY-JZ
CU/PVC/GSWB/PVC On request

YSLYSY-JZ

PVC steel-braided flexible control cable, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V CPR Eca EN 50525-2-51 →
3D view of the construction of H05VVC4V5-K
CU/PVC/PVC/TCWB/PVC On request

H05VVC4V5-K

Oil-resistant screened flexible control cable, 300/500 V

Lead time: On request; the lead time is stated in the quote.

300/500 V EN 50525-2-51 →
3D view of the construction of LiYY
CU/PVC/PVC On request

LiYY

PVC flexible data cable, unscreened

Lead time: On request; the lead time is stated in the quote.

250 V CPR Eca DIN VDE 0812 →
3D view of the construction of LiHCH
CU/LSZH/TCWB/LSZH On request

LiHCH

LSZH flexible data cable, screened

Lead time: On request; the lead time is stated in the quote.

250 V DIN VDE 0812 →

Screened or unscreened

An unscreened cable such as YSLY-JZ or YSLY-OZ is enough for supply and simple control where there is no interference. Where the cable runs past variable-speed drives, motors or measuring signals, choose a screened version: YSLYCY-JZ and LiYCY have a copper braid that limits pick-up and emission. The screen only works if you earth it correctly on at least one side.

LiYCY is the fine-stranded data and signal cable with a braid screen; LiYCY-TP has twisted pairs for better signal transmission. LiYY is the unscreened version for low-frequency signals and data indoors. For core colours these types generally follow DIN 47100.

Where the cable moves

Machine building often needs cable that flexes on a moving part. In that case, check the bending radius: for these types it is 10 to 20 × the outer diameter when flexing, against 4 to 12 × for fixed installation. Check the temperature range when flexing as well; the values for each type are on its product page. These types are made for fixed installation and occasional free movement. For a drag chain, where the cable moves back and forth continuously, choose the PUR drag-chain cable JZ. YSLYSY-JZ adds a steel wire braid for mechanical protection where the cable may be knocked or pinched.

From stock or to order

LiYCY, LiYCY-TP and LiHCH-TP are in stock in Dordrecht; we supply the other control and signal cables to order. Send the type, the number of cores or pairs, the cross-section and the length, and we will quote the price with the lead time included, not after it.

Side by side
Type Voltage CPR Standard Conductor Availability and lead time
LiHCH-TP 250 V - DIN VDE 0812 Fine-stranded bare copper (class 5 acc. to IEC 60228 from 0.5 mm²) In stock 1–2 working days from stock
LiYCY 250 V Eca DIN VDE 0812 Fine-stranded bare copper (class 5 acc. to IEC 60228 from 0.5 mm²) In stock 1–2 working days from stock
LiYCY-TP 250 V Eca DIN VDE 0812 Fine-stranded bare copper In stock 1–2 working days from stock
YSLY-JZ 300/500 V Eca Based on EN 50525-2-51 Copper, bare, class 5 (fine stranded / flexible), IEC 60228 On request The lead time is stated in the quote.
YSLY-OZ 300/500 V Eca Based on EN 50525-2 Fine-wire stranded plain annealed copper, class 5 to IEC/EN 60228 (VDE 0295) On request The lead time is stated in the quote.
YY-LSZH 300/500 V Dca Based on EN 50525-3-11 Plain (bare) annealed copper, fine-stranded, class 5 to IEC/EN 60228 On request The lead time is stated in the quote.
YSLYCY-JZ 300/500 V Eca Based on EN 50525-2-51 Fine-wire stranded plain (bare) copper, class 5 to IEC/EN 60228 On request The lead time is stated in the quote.
YSLYCY-OZ 300/500 V Eca Based on EN 50525-2-51 Fine-stranded plain (bare) copper, class 5 acc. to IEC/EN 60228 (VDE 0295) On request The lead time is stated in the quote.
YSLYSY-JZ 300/500 V Eca Based on EN 50525-2-51 Plain (bare) copper, class 5 fine-stranded (flexible), IEC/EN 60228 On request The lead time is stated in the quote.
H05VVC4V5-K 300/500 V - EN 50525-2-51 Fine-wire stranded bare copper, class 5 to IEC/EN 60228 On request The lead time is stated in the quote.
LiYY 250 V Eca DIN VDE 0812 Bare copper, fine-stranded to IEC 60228 / VDE 0295 class 5 (0.34 mm²: 7 × 0.25 mm) On request The lead time is stated in the quote.
LiHCH 250 V - DIN VDE 0812 Fine-stranded bare copper (class 5 acc. to IEC 60228 from 0.5 mm²) On request The lead time is stated in the quote.
Frequently asked questions
Is YY the same as YSLY-JZ?

Yes. YY is a shorter name for the same unscreened PVC control cable: fine-stranded copper cores, black and numbered, with a green/yellow core from three cores up (JZ). In the same way CY and YSLYCY-JZ are the same, as are SY and YSLYSY-JZ. Without a green/yellow core the cable is called YSLY-OZ. With cores coloured to HD 308 it is YSLY-JB.

When do I choose YSLYCY-JZ instead of YSLY-JZ?

YSLYCY-JZ has a copper braid screen and YSLY-JZ does not. Choose YSLYCY-JZ as soon as the cable runs past sources of interference (variable-speed drives, large motors) or carries sensitive signals itself. In a clean environment without interference, YSLY-JZ is enough.

Are these cables suitable for a drag chain?

Only the PUR drag-chain cable JZ. The other types are made for fixed installation and occasional free movement, not for continuous flexing. Give us the travel length, the number of cycles per hour and the smallest radius in the chain, and we will work out the right type.

Read more

Quote

Request control and signal cable

Send type, number of cores or pairs, cross-section and whether screening is needed. We will let you know quickly which type fits and what the lead time is.

Not seeing what you need? Just ask. Our range goes well beyond this list.

Send your enquiry

Include cross-section, length and required delivery date, and we can get straight to work.

1Which cable?
Type unknown? Fill in the specification (optional)
2How much and when?
3Your details
A fast response on working days, often the same working day. No account and no webshop: one email is enough.

Have a cable list (Excel, CSV or PDF)? Email it to info@qcables.nl and we will include it in the quote.