Skip to content
Control & signal

YSLYSY-JZ

PVC steel-braided flexible control cable, 300/500 V

300/500 V CPR Eca Based on EN 50525-2-51
CU/PVC/GSWB/PVC On request Lead time: On request; the lead time is stated in the quote. Send your enquiry
Application

YSLYSY-JZ (also known as SY) is the control cable with a galvanised steel wire braid: mechanical protection where the cable may be knocked or pinched, plus a degree of screening. The transparent sheath shows the braid, so you spot damage or corrosion early. Supplied to order; the lead time is stated in the quote.

YSLYSY-JZ (also known as SY) is a flexible multicore control cable with class 5 plain copper conductors, PVC-insulated cores, a PVC inner sheath, a galvanised steel wire braid and a transparent PVC outer sheath, rated 300/500 V. The steel braid gives mechanical protection and a degree of screening, while the transparent sheath allows visual inspection of the braid for damage or corrosion. It is used for the interconnection of control, measuring and regulating equipment in machine tools, production and assembly lines, conveyors and air-conditioning plant, indoors or in dry to damp locations, for fixed installation and occasional flexing. It is not designed for continuous flexing, drag chains or burial outdoors. Where a low-smoke zero-halogen cable is required, specify an LSZH version instead.

Steel braidedMechanically robustMachine building

Also known as: SY · YSLYSY-JB · steel-braided control cable

Applications

  • Control wiring in machine tools, conveyors and air-conditioning plant.
  • Locations with a risk of mechanical damage where YSLY-JZ is too light.
  • Applications where you need to check the steel braid for damage or corrosion.

What to look out for

  • The steel braid is not a full EMC screen; for strict EMC requirements choose YSLYCY-JZ.
  • Not for continuous flexing in drag chains or unprotected outdoor use.
  • CPR class Eca. Where the cable is installed permanently in a building and exposed to indoor air, the Bbl requires at least Dca. The wiring inside a control panel or machine is not covered by that requirement, but the cables running to it are.
Construction
Conductor
Plain (bare) copper, class 5 fine-stranded (flexible), IEC/EN 60228.
Insulation
PVC, type YI2.
Bedding
PVC inner sheath, type YM2.
Braid
Galvanised steel wire braid (GSWB) of round or flat steel wires.
Sheath
PVC, type YM2, transparent.
Core identification
Black cores with white numbers; green/yellow earth core from 3 cores. Also available with coloured cores to HD 308 (JB/OB) on request.
Electrical & thermal properties
Rated voltage Uo/U
300/500 V.
Standard
Based on EN 50525-2-51 (not harmonised).
Test voltage
4,000 V.
Flame-retardant
IEC/EN 60332-1-2.
Conductor standard
IEC/EN 60228, class 5.
Max. conductor temperature
70 °C.
Permitted ambient temperature, fixed
−40 °C to +70 °C.
Permitted ambient temperature, flexing
+5 °C to +70 °C.
Oil resistance
Largely oil-resistant.
Min. bending radius, fixed
12 × outer diameter.
Min. bending radius, flexing
20 × outer diameter.
Reaction to fire (CPR)
Eca acc. to EN 50575.
Dimensions and technical data

Sizes and weights

Cores × mm²R DC 20 °C (Ω/km)Outer Ø approx. (mm)Weight approx. (kg/km)
2×0.5397.480
3×0.5397.792
4×0.5398.1102
5×0.5399119
7×0.5399.5157
10×0.53910.8205
12×0.53911.8218
14×0.53912.5242
18×0.53913.7340
21×0.53914.3370
25×0.53915.8406
30×0.53916.7439
35×0.53917.9500
40×0.53918.5565
42×0.53919.4593
50×0.53920.9690
61×0.53922.1843
80×0.53925.41050
100×0.53928.11240
2×0.75267.998
3×0.75268.2103
4×0.75269.1122
5×0.75269.7142
6×0.752610.5180
7×0.752610.5185
8×0.752611.1201
9×0.752612.1249
10×0.752612.1252
12×0.752613.2292
15×0.752614.4335
18×0.752615.2388
21×0.752616.2474
25×0.752617.7503
32×0.752619.5644
34×0.752620.1663
41×0.752621.5741
50×0.752623.6925
61×0.7526251082
2×119.58.2112
3×119.59132
4×119.59.5143
5×119.510.1166
6×119.510.9220
7×119.510.9227
8×119.512277
9×119.512.8295
12×119.513.9340
14×119.514.7420
18×119.516.3500
20×119.517532
25×119.518.6664
34×119.521.3845
36×119.521.3857
41×119.523993
50×119.525.31112
56×119.525.91225
61×119.526.91306
65×119.527.81504
80×119.530.71750
100×119.533.91950
2×1.513.39.2129
3×1.513.39.6149
4×1.513.310.4185
5×1.513.311.1205
6×1.513.312.2255
7×1.513.312.2285
8×1.513.313.2340
9×1.513.314.1347
10×1.513.314.1418
11×1.513.314.1430
12×1.513.315.3444
14×1.513.316.4533
18×1.513.318593
25×1.513.321781
32×1.513.323.11015
34×1.513.3241124
42×1.513.325.91401
50×1.513.328.41583
61×1.513.330.21810
80×1.513.334.42316
100×1.513.338.42900
2×2.57.9810.6185
3×2.57.9811.1248
4×2.57.9812.2290
5×2.57.9813.3347
7×2.57.9814.2420
12×2.57.9818.3660
14×2.57.9819.7750
18×2.57.9821.6893
20×2.57.98231169
25×2.57.9825.61458
30×2.57.9827.31686
34×2.57.9829.41869
50×2.57.9834.72200
61×2.57.9836.83000
3×44.9512.6350
4×44.9513.9428
5×44.9515.2504
7×44.9516.6640
11×44.9519.71204
4×63.316.4571
5×63.317.9671
7×63.319.6845
4×101.9119.9943
5×101.91221065
7×101.91241551
4×161.2124.11360
5×161.2126.71740
7×161.2129.22166
4×250.7829.12020
5×250.7832.22465
4×350.55432.12570
5×350.55435.53185
4×500.38637.93513
5×500.386424248
4×700.272434810
5×700.27247.85880
4×950.20649.66360
5×950.20654.88071
4×1200.16154.68170
4×1500.12959.89970

Nominal values; conductor resistance is the maximum to IEC 60228, class 5. All values are indicative.

Which one do I choose?

YSLYSY-JZ or YSLYCY-JZ?

YSLYSY-JZ

  • galvanised steel wire braid
  • mechanical protection

YSLYCY-JZ

  • tinned copper braid
  • EMC screen

Both have a braid, but for a different purpose. YSLYSY-JZ has a galvanised steel wire braid under a transparent sheath, for mechanical protection. YSLYCY-JZ has a tinned copper braid as an EMC screen. Choose YSLYSY-JZ where the cable may be knocked or pinched, and YSLYCY-JZ where interference from drives or motors must be kept out of the cable.

View YSLYCY-JZ →

YSLYSY-JZ or YSLY-JZ?

YSLYSY-JZ

  • galvanised steel wire braid
  • inner and outer sheath

YSLY-JZ

  • no braid
  • single PVC sheath

YSLY-JZ is the unscreened control cable with a PVC sheath. YSLYSY-JZ has the same kind of numbered cores, but with a PVC inner sheath, a galvanised steel wire braid and a transparent outer sheath. The braid protects against knocks and pinching, and the sheath lets you see damage or corrosion on the braid. Choose YSLYSY-JZ where YSLY-JZ is mechanically too light, and YSLY-JZ in cabinets and trays.

View YSLY-JZ →