BU 0.6/1 kV

NEK 606 offshore fire-resistant power cable, halogen-free, unarmoured

0.6/1 kV NEK TS 606
CU/MGT/EPR/SHF2 On request Lead time: On request; the lead time is stated in the quote. Send your enquiry
Application

BU 0.6/1 kV is the fire-resistant, unarmoured offshore power cable: mica-tape barrier for circuit integrity in a fire, without the copper braid. For emergency and safety circuits in safe areas where no armour is needed. Supplied to order; the lead time is stated in the quote.

BU 0.6/1 kV is a fire-resistant, flame-retardant, halogen-free and drilling-mud-resistant power and control cable for fixed installation on offshore units, drilling rigs, FPSOs and ships, designed to NEK TS 606 (code P17, now P110) and IEC 60092-353. The tinned copper conductors are wrapped with a mica tape fire barrier, insulated with halogen-free EPR and protected by a halogen-free, flame-retardant and drilling-mud-resistant thermoset outer sheath; the cable has no braid armour. It is intended for power, lighting and control circuits below 1 kV that must keep functioning during a fire, such as emergency and safety systems, fire-fighting circuits and other critical services in safe areas. Where mechanical protection or electromagnetic screening by a metal braid is required, the armoured version (BFOU) should be used instead.

NEK 606Fire-resistantUnarmoured

Also known as: fire-resistant offshore cable

Applications

  • Emergency and safety circuits with circuit integrity where no armour is needed.
  • Fire-fighting circuits and critical services below 1 kV in safe areas.
  • Protected routes on platforms, FPSOs and ships.

What to look out for

  • Unarmoured: where mechanical protection or a metallic EMC screen is needed, choose BFOU.
  • Circuit integrity to IEC 60331 applies to the cable; brackets, penetrations and terminals must survive the same fire time, or the circuit fails anyway. Metal brackets, no plastic.
Construction
Conductor
Tinned annealed stranded circular copper, class 2 acc. to IEC 60228.
Fire barrier
Mica (glass) tape applied over the conductor.
Insulation
Halogen-free EPR compound.
Outer sheath
Halogen-free, flame-retardant and drilling-mud-resistant thermoset compound (SHF2), black; no armour.
Core identification
Up to 4 cores: coloured cores acc. to NEK TS 606 (1: black; 2: blue, brown; 3: brown, black, grey; 4: blue, brown, black, grey); 5 cores and more: white cores with black numbers.
Electrical & thermal properties
Rated voltage Uo/U
0.6/1 kV (max. operating voltage 1.2 kV).
Test voltage
3.5 kV.
Standard
NEK TS 606 (code P17 / P110); design acc. to IEC 60092-353; conductors acc. to IEC 60228.
Fire-resistant
Acc. to IEC 60331-21 (IEC 60331-1/-2).
Flame-retardant
Acc. to IEC 60332-1-2 and IEC 60332-3-22 Cat. A.
Halogen-free
Acc. to IEC 60754-1/-2; low smoke density acc. to IEC 61034-1/-2.
Drilling-mud resistant
Yes, sheath resistant to oil and drilling mud acc. to NEK TS 606.
Max. conductor temperature
+90 °C.
Permitted outer cable temperature, fixed
−15 °C to +90 °C.
Min. bending radius, fixed
6 × outer diameter (8 × outer diameter during installation).
Reaction to fire (CPR)
Outside the scope of EN 50575 (offshore and shipboard cable).
Which one do I choose?

BU or BFOU?

BU 0.6/1 kV

  • no braid
  • circuit integrity, IEC 60331

BFOU

  • inner sheath and tinned braid
  • circuit integrity, IEC 60331

BU is the unarmoured fire-resistant cable: mica tape and EPR insulation under a halogen-free SHF2 sheath, without a braid. BFOU also has circuit integrity to IEC 60331, plus an inner sheath and a tinned copper braid. BU is lighter and more flexible and suits protected routes. If the cable can be mechanically damaged or a metallic screen is needed, it becomes BFOU.

View BFOU 0.6/1 kV →

BU or RU?

BU 0.6/1 kV

  • circuit integrity, IEC 60331-21
  • unarmoured and halogen-free

RU

  • flame-retardant only
  • unarmoured and halogen-free

Both are unarmoured and halogen-free, with EPR insulation and an SHF2 sheath. BU also has a mica tape around each conductor and keeps working in a fire to IEC 60331-21. RU is flame-retardant only. Choose BU for circuits that need circuit integrity, such as emergency and safety systems, and RU for ordinary power and control circuits.

View RU 0.6/1 kV →