RS-485 2×2×0.20 PE UV
RS-485 bus cable, 2 pairs 0.20 mm², 120 Ω, foil and tinned-copper braid, UV-resistant PE sheath
RS-485 2×2×0.20 PE UV is the two-pair bus cable for outdoors: 120 Ω, foil plus tinned-copper braid and a black, UV-resistant PE sheath. Supplied to order; the lead time is stated in the quote.
RS-485 2×2×0.20 PE UV is an RS-485 (EIA/TIA-485) data bus cable with a characteristic impedance of 120 Ω, for serial fieldbus communication between PLCs, drives, operator panels, meters and SCADA/RTU equipment. Two twisted pairs of stranded tinned-copper conductors with polyethylene (PE) insulation are enclosed by an overall screen of aluminium/polyester (Al/PET) foil with a tinned-copper drain wire and a tinned-copper braid, which keeps the bus reliable in electrically noisy installations and over long distances. The black PE sheath is UV-resistant, for routes exposed to sunlight.
Also known as: RS485 cable · Modbus cable · fieldbus cable
Applications
- Four-wire RS-485 or a bus with a separate reference pair, outdoors.
- Bus cable between outdoor cabinets, meters and inverters.
What to look out for
- CPR class Fca: for outdoors. Inside a building, where the cable is exposed to indoor air, the Bbl requires at least Dca.
- The second pair is for four-wire RS-485 (full duplex) or for the signal reference (common) that many devices ask for.
- Conductor
- Stranded tinned copper, 7 × 0.19 mm (±0.008 mm), approx. 0.20 mm².
- Insulation
- Polyethylene (PE), nominal diameter 1.80 mm (±0.13 mm).
- Pairs
- Two twisted pairs; colours blue/white and white/blue, orange/white and white/orange.
- Screen
- Overall aluminium/polyester (Al/PET) foil with a stranded tinned-copper drain wire, 7 × 0.19 mm.
- Braid
- Tinned copper, 112 × 0.12 mm, coverage 90%.
- Sheath
- Polyethylene (PE), UV-resistant, black.
- Cross-reference
- Comparable to Belden 9842 (RS-485, 2 pairs). Differs in outer diameter (6.80 mm instead of 8.64 mm), sheath (UV-resistant PE instead of PVC) and conductor (7 × 0.19 mm instead of 7 × 0.20 mm).
- Rated voltage
- 300 V.
- Characteristic impedance
- 120 Ω.
- Mutual capacitance
- 42 pF/m (conductor to conductor).
- Conductor resistance
- max. 96 Ω/km at 20 °C.
- Temperature range
- −30 °C to +80 °C.
- Compliance
- RoHS (EU 2015/863) and REACH.
- Reaction to fire (CPR)
- Fca (EN 50575).
Key figures
| Pairs × mm² | Outer Ø (mm) | Impedance (Ω) | R 20 °C (Ω/km) |
|---|---|---|---|
| 2×2×0.20 | 6.80 ±0.20 | 120 | max. 96 |
Manufacturer's nominal values for this construction, with the tolerances from the sheet. Weight and minimum bending radius on request. Belden is a trademark of Belden Inc.; the name is used for comparison only.
Two pairs or one for outdoors?
RS-485 2×2×0.20 PE UV
- two pairs, also for four-wire
- Ø 6.80 mm
RS-485 1×2×0.20 PE UV
- one pair
- Ø 5.90 mm
For a two-wire bus (half duplex) you use one pair. The second pair is for four-wire RS-485 (full duplex), with a separate pair for transmit and receive, or for the signal reference (common) that many devices ask for. Screen, impedance and sheath are otherwise the same.
View RS-485 1×2×0.20 PE UV →PE UV or LSZH with two pairs?
RS-485 2×2×0.20 PE UV
- UV-resistant PE sheath
- CPR Fca
RS-485 2×2×0.20 LSZH
- halogen-free LSZH sheath
- CPR Eca
Construction and electrical values are the same. The PE version has a black UV-resistant sheath for routes in the sun and is Fca. The LSZH version has a grey halogen-free sheath and is Eca.
View RS-485 2×2×0.20 LSZH →